Attack Hose |
Hose designed to be used to combat fires beyond the incipient stage. |
|
Attack hose shall have a minimum design operating test pressure of 275 psi. |
Attack Hose-1� Booster Line |
Rubber Hose:
- Used for Rubbish, Brush, Washdowns
- Requires High Pressure (approx. 200 psi)
- Delivers low volume (approx. 50 gpm)
- Highly mobile - can be handled by 1 firefighter
- Uses a fog type nozzle
|
|
|
Attack Hose -1 3/4" |
Primary Attack Line for House and Vehicle Fires |
|
Double Jacketed
- 275 psi max. operating pressure
|
|
Can be operated by 2 - 3 firefighters |
|
Can deliver 140 - 200 gpm |
|
Working pressure and volume varies with nozzle type |
|
Used with both solid bore and fog type nozzles |
|
|
Attack Hose - 2 1/2" |
Primary attack line in Commercial Buildings and Exterior attacks |
|
Used to back up smaller hand lines |
|
Double Jacketed
- 275 psi max. operating pressure
|
|
Needs 3 - 4 or more firefighters to operate |
|
Delivers high volume of water (200- 300 gpm) |
|
Relatively difficult to operate, especially in tight spaces |
|
Used with both solid bore and fog type nozzles |
|
|